0 of 40 Questions completed
Questions:
You have already completed the examination before. Hence you can not start it again.
Examination is loading…
You must sign in or sign up to start the examination.
You must first complete the following:
0 of 40 Questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Thank you!
For the diffusion of solute A through a layer of gas to an absorbing liquid, with yA = 0.20
and yAi= 0.10:
Calculate the transfer rate for one-way diffusion compared to that for equimolal
diffusion. (in terms of percentage)
For the diffusion of solute A through a layer of gas to an absorbing liquid, with yA = 0.20
and yAi= 0.10:
What is the value of yA halfway through the layer for one-way diffusion?
Ammonia (A) being absorbed from air (B) into water is an example of
The diffusivity of water in air at 100°F and 1atm in cm²/sec is?
The flux of A in unicomponent diffusion is greater than in equimolal diffusion because of
Ammonia is diffusing through a stagnant gas mixture consisting of 1/3 nitrogen and 2/3
hydrogen by volume. The total pressure is 30 psia and the temperature is 30°F. The
concentration of ammonia across the film which is 0.5mm thick drops from 10% to 5%
ammonia by volume. Assuming the mass diffusivity of ammonia to be 0.229 cm²/sec, the rate
of diffusion of ammonia expressed in lb/hr-ft² through the film is?
A tank containing water has its top open to air. The tank is cylindrical with diameter of 1m.
The liquid level is maintained at a level 1m below the top of the tank. The diffusivity of water
to air at 310K at 1atm is 0.273 cm²/s. The vapor pressure of water at 310K is 10.73 kPa. How
many moles of water are lost per hour at 310K if dry air is blown across the top of the tank?
It is a measure of the diffusive mobility of individual molecules in solution.
Calculate the rate of diffusion of NaCl (in mol/m²-s) across a film of water (non-diffusing)
solution 1.5mm thick at 18°C when the concentrations on opposite sides of the film are 24 and
4 wt% NaCl respectively. The diffusivity of NaCl is 1.3E-5 cm²/s at 18°C. Densities of 24 and
4 wt% NaCl at 18°C are 1081 and 1027 kg/m³ respectively.
It represents the total mass transferred to mass transferred by molecular diffusion
He and N₂ gas are contained in a conduit 5mm in diameter and a 0.1 m long at 298K and a
uniform pressure of He at one end of the tube is 0.6 atm and 0.02 atm at the other end.
Assuming equimolar countercurrent diffusion, the flux in kmol/s-m² is?
A mixture of He and N₂ gas is confined in a pipe at 298K and 1atm total pressure which is
constant throughout. At one end of the pipe at point 1, the partial pressure of He is 0.60 atm
and at the other end at 0.2m is 0.20 atm. Calculate the flux of He in kmol/s-m² at steady state
if the diffusivity of He in N₂ is 0.687E-4 m²/s.
Ammonia gas is diffusing at a constant rate through a layer of stagnant air 1 mm thick.
Conditions are fixed so that the gas contains 50% by volume of ammonia at one boundary of
the stagnant layer. The ammonia diffusing to the other boundary is quickly absorbed and the
concentration is negligible at that plane. The temperature is 295 K and the pressure
atmospheric, and under these conditions the diffusivity of ammonia in air is 0.18 cm²/s.
Calculate the rate of diffusion of ammonia through the layer.
A rectangular tank 1 ft² in cross section and 6” depth is filled with ethyl alcohol solution in
water at 50°F to within 0.75” of the top. A fan is blowing air at 50°F at 1atm over the tank.
Alcohol concentration at the interface is 0.65 mole fraction. The diffusivity of ethyl alcohol is
0.417 ft²/hr. How much alcohol will be lost (in lbmol/day) in one day by diffusion? Assume
that alcohol level is maintained constant.
0.6m³/s (measured at STP) of gas is to be dried from a dew point of 294K to a dew point of
277.5K. Vapor pressure of water at 294K is 2.5kN/m². Vapor pressure of water at 277K is
0.85kN/m². What will be the volume of the gas after drying (measured at STP)?
The temperature at which the moisture in humid air exerts a partial pressure equal to its vapor
pressure is called the
Air at 100kPa pressure and a dry-bulb temperature of 93°C and wet-bulb temperature
of 35°C is fed to a dryer. In the dryer, 0.03 kmol of water evaporates per kmol of air fed to the
dryer.
If the vaporization of water in the dryer is adiabatic, calculate the wet-bulb
temperature of the air leaving the dryer.
Air at 100kPa pressure and a dry-bulb temperature of 93°C and wet-bulb temperature
of 35°C is fed to a dryer. In the dryer, 0.03 kmol of water evaporates per kmol of air fed to the
dryer.
Calculate the percentage saturation of the air leaving the dryer.
An indication of the moisture content of ambient air is its
In an air-conditioning system, 1 kg/s air at 350 K and 10 per cent humidity is mixed
with 5 kg/s air at 300 K and 30 per cent humidity.
What is the humidity of the resultant stream?
In an air-conditioning system, 1 kg/s air at 350 K and 10 per cent humidity is mixed
with 5 kg/s air at 300 K and 30 per cent humidity.
What is the enthalpy of the resultant stream?
In an air-conditioning system, 1 kg/s air at 350 K and 10 per cent humidity is mixed
with 5 kg/s air at 300 K and 30 per cent humidity.
What is the temperature of the resultant stream
The relative humidity of air at a given temperature is the
Given a mixture of air and water at 85°F dry bulb temperature and 68°F wet bulb
temperature, calculate the following:
Percent relative humidity (using humidity chart)
Given a mixture of air and water at 85°F dry bulb temperature and 68°F wet bulb
temperature, calculate the following:
Heat of vaporization in BTU per lb water
Given a mixture of air and water at 85°F dry bulb temperature and 68°F wet bulb
temperature, calculate the following:
Vapor pressure of water in psia
Given a mixture of air and water at 85°F dry bulb temperature and 68°F wet bulb
temperature, calculate the following:
Partial pressure of water in psia
The portion of water in the wet solid that cannot be removed by the air in direct contact with
the solid is called
The rate of drying at constant rate period is 20 lbs/hr. 400 lbs of dry solid containing 300 lbs
water enter the drier. If the critical free moisture is 0.05 (d.b.), the drying time to dry the
material to 5% moisture (w.b.) is:
Consider the drying operation with critical moisture content of 0.10 and an equilibrium
moisture content of 0.005 and for a solid loading (dry basis) of 50 kg/m² with a constant drying
rate of 5kg/m²-hr. The falling rate of drying is linear with moisture content. The drying time
(in hrs) required to reduce an initial moisture content of 25% to a final moisture content of 2%
is:
A batch drier removes water from a solid material at a rate of 30 lb/hr during the constant rate
period. Under the operating conditions, the critical free moisture content is 0.5 lb H₂O/lb dry
solid, and the equilibrium moisture content is 0.04 lb H₂O/lb dry solid. The curve of drying
rate versus moisture content may be assumed as a straight line during the entire falling rate
period. Three hundred pounds of dry solid, containing 200 lb of water, enters the drier. How
long will the total drying require if the final product contains 0.08 lb of water per lb of dry
solid?
One thousand kilograms per hour of a material with 30% moisture content (d.b.) is dried in a
belt conveyor drier with a capacity of 50kg of bone-dry solid per meter of dryer. The total
drying time is 5.3 hours. Estimate the length of the drier.
The free-moisture content of the solid does not depend upon
Wet solids are to be dried from 36% to 8% moisture in 5 hours under constant drying
conditions. Xₜ꜀ = 14%, Xₑ = 4%. All moisture contents are on a dry basis. The additional time
it will take to dry from 8% to 5.5% moisture under the same drying conditions is:
The amount of water to be removed from 2,000 kg/hr of feed to be dried from 110% (d.b.) to
5% (w.b.) is __ kg/hr.
Coffee extract containing 70% water is to be spray dried using air at 420 K in a 6-m diameter
by 6-m high chamber with centrifugal disk atomizer. The capacity of the spray drier is ___
lb/hr of feed, if the final product will have a moisture content of 1% (w.b.).
In drying at the falling rate period, the rate at which moisture is removed from the solid material
Wet solids are to be dried from 40% to 10% in 5 hours under constant drying conditions. The
critical moisture content is 20% and the equilibrium moisture content is 7%. All moisture
contents are on a dry basis. The time needed to dry from 15% to 5% free moisture under the
same drying conditions is
1 Mg of dry mass of a non-porous solid is dried under constant drying conditions in an air
stream flowing at 0.75 m/s. The area of surface drying is 55 m2. If the initial rate of drying is
0.3 g/m2s, how long will it take to dry the material from 0.15 to 0.025 kg water/kg dry solid?
The critical moisture content of the material may be taken as 0.125 kg water/kg dry solid.
A wet solid is dried from 40 to 8 per cent moisture in 20 ks. If the critical and the equilibrium
moisture contents are 15 and 4 per cent respectively, how long will it take to dry the solid to 5
per cent moisture under the drying conditions? All moisture contents are on a dry basis.